Three brush dynamos
On three brush dynamos, there are no regulator, only a
charging relay. The output is regulated by a third brush that collects sufficient
energy for the field windings.
Sometimes there are more field windings to compensate for different loads, or,
the light switch are double, one side turning the light on, the other side
shorting a resistor in series with the field winding
|
Three brush dynamo coupled
as an A-type dynamo
|
|
|
|
Three brush dynamo, couple
as a B-type dynamo
|
|
Three
brush dynamos are relatively easy to convert to two brush with regulator.
remove the third brush, and connect the regulator F connection to the brush holder.
With more field windings examine which is the main
winding, and use this, and examine whether it is an A- or B-type dynamo,
see: Which type. (third brush removed under this test)
|
Three brush dynamo of
A-type converted with regulator
|
|
|
|
Three brush
dynamo of D-type, converted with
regulator
|
|
On certain
systems like early Harley Davidson, help windings can be left unchanged.
|
|
|
|
|
Example of early Harley dynamo (1930-31) converted with
A-regulator. The second winding is connected to the lightswitch,
and only adds a couple of Amps. this can left unchanged
Later Harley Davidson use a system more like the Morgan system belowr |
|
|
|
|
|
|
|
|
|
|
|
Example of Morgan system, converted with B-regulator
*If the ampere meter is mounted in the battery ground
connection, the regulator "A" is to be connected to the
battery |
|
|
|
|
|
|
|
|